Fingertip Pluse Oximeter(L...

JH-PX01

The Pulse Oximeter can be used to measure human Hemoglobin Saturation and heart rate thyough finger.The product is suitable for use in family, hospital, Oxygen Bar,social medical organizations, physical care in sports and etc.

1.Lightweight fir carrying and easy to use.

2.Manually adjust the direction of interface.

3.Color LED diaplay simulataneous display for testing value and plethysmogram.

4.Low perfusion down to 0.3%.

5.Visual alarm function, real-time spotchecks.

6.Low battery voltage indicator.

7.Automatically switch off.

8.Standard two AAA 1.5V Alkaline batteries support more than 20 hours continuous work.

Physical Characteristics
Machine:
Dimension: 60mm (L) x 35mm (W) x 32mm (H)
Weight: 50g(including 2 AAA akaline batteries
Outer box: 80mm (L) x 60mm (W) x 52mm (H)
Gross weight: 70g
Classification:
Anti-electronic Shock Type: Internally powered equipment
Anit-electronic Shock Degree:Type BF equipment
EMC: Type B class I
Mode of operation: Continuous Operation Enclosure Degree of ingress

Protection: IPX4

Power:

Internal
2 AAA 1.5V akaline batteries
Power consumption
Smaller than 30mA (Normal)

Power consumption:

Operating Temperature
5℃-40℃
Storage Temperature
-10℃-50℃
Relative Humidity
15%-80% non-condensing

Alarm default value

Parameter
Value
Hemoglobin saturation

Upper limit: 100

Bottom limit: 94

Pulse rate

Upper limit: 130

Bottom limit: 50

Alarm default value











Parameters
Value
Hemoglobin saturation display
35-100%
Pulse rate display
30-250 BPM
Resolution
Hemoglobin saturation
1%
Pulse rate
1 BPM
Measure Accuracy
Hemoglobin saturation
2%(70%-100%) Unspecified(<=70%)
Pulse rate
2 BPM

1.Do not use the pulse oximeter together with MRI or CT equipment.
2.Explosion hazard:Do not use the pulse oximeter in an
explosive atmosphere.
3.The pulse oximeter is intended only as an adjunct in patient assessment.Doctors should make
diagnosis in conjunction with clinical manifestation and symptoms.
4.Check the pulse oximeter sensor application site frequently to make sure that the circulation
and skin integrality of patient are under good condition.
5. Do not stretch the adhesive tape while applying the pulse oximeter sensor This may cause
inaccurate reading or skin blisters.
6.Inaccurate measurements may be causes by autociaving,ethylene oxide sterlizing,or immersing
the sensors in liquid
7.Hypotension,severe vasoconstriction,severe anemia,or hypothermia may cause inaccurate reading
8.Significant levels of dysfunctional hemoglobins (such as carboxyl - hemoglobin or methemoglobin)
may cause inaccurate reading.
9.Unexpected action may cause inaccurate reading.
10.Bright nail or painted nail may cause inaccurate Sp02 reading.

1.One hand lace

2.Two batteries

3.One user manual book