Blood pulse oximeter

JH-PX03

OLED display
1.Product adopts double color OLED display, can show the six different display mode
2.Low-power consumption, continuously work for 40 hours
3.Low voltage indicator
4.In the absence of signals, the product will be in after
5.8 seconds to enter standby state
6.Small in volume, light in weight, and convenient to carry

Display Type:

OLED display

SpO2:

Measurement range 70%~99%

Accuracy ±2% on the stage of 70%~90%

Unspecified(≤70%for SpO2

Resolution:

±1%

Measurement range:

30BPM ~240BPM

Accuracy:

±1BPM or ±1% (the larger one)

Power:

two AAA 1.5V alkaline batteries

Power consumption:

below 30mA

Automatic power-off:

the product shuts off by itself when no finger is in the product in 8 seconds

Dimension:

58mm x 36mm x33mm

Operation Environment:

Operation Temperature: 5 ℃ ~40 ℃

Storage Temperature: -10 ℃ ~ 40 ℃



Interference Resistance Capacity

against Ambient Light:

Device works normally when Pulse Oximeter

tester exerts interfering signal test

Ambient Humidity:

15% ~80% on operation

10% ~80% in storage

Air Pressure:

70kPa ~ 106kPa

Declaration:

EMC of this product comply with IEC60601-1-2 standard

Measurement Performance in Low

Perfusion Condition:

required test equipment (Pulse Oximeter tester)

could measure the available pulse wave with the amplitude of 6% of the simulation pulse wave amplitude.



1.Do not use the pulse oximeter together with MRI or CT equipment.
2.Explosion hazard:Do not use the pulse oximeter in an
explosive atmosphere.
3.The pulse oximeter is intended only as an adjunct in patient assessment.Doctors should make
diagnosis in conjunction with clinical manifestation and symptoms.
4.Check the pulse oximeter sensor application site frequently to make sure that the circulation
and skin integrality of patient are under good condition.
5. Do not stretch the adhesive tape while applying the pulse oximeter sensor This may cause
inaccurate reading or skin blisters.
6.Inaccurate measurements may be causes by autociaving,ethylene oxide sterlizing,or immersing
the sensors in liquid
7.Hypotension,severe vasoconstriction,severe anemia,or hypothermia may cause inaccurate reading
8.Significant levels of dysfunctional hemoglobins (such as carboxyl - hemoglobin or methemoglobin)
may cause inaccurate reading.
9.Unexpected action may cause inaccurate reading.
10.Bright nail or painted nail may cause inaccurate Sp02 reading.

1.One hand lace

2.Two batteries

3.One user manual book